• Users Online: 337
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2018  |  Volume : 8  |  Issue : 3  |  Page : 125-139

Noninvasive optical diagnostic techniques for mobile blood glucose and bilirubin monitoring


Department of Computer Engineering and Information Technology, University of Qom, Qom, Iran

Correspondence Address:
Faranak Fotouhi-Ghazvini
Department of Computer Engineering and Information Technology, University of Qom, Qom
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmss.JMSS_8_18

Rights and Permissions

Background: People with diabetes need to monitor their blood sugar levels constantly and attend health centers regularly for checkups. The aim of this study is to provide a healthcare system for mobile blood glucose and bilirubin monitoring. Methods: It includes a sensor for noninvasive blood glucose and bilirubin measurement using near-infrared spectroscopy and optical method, respectively, communicating with a smartphone. Results: It was observed that by increasing the glucose concentration, the output voltage of the sensor increases in transmittance mode and decreases in reflectance mode. Moreover, it was observed that by increasing the bilirubin concentration, the output voltage of sensor decreases in transmittance mode and increases in reflectance mode. In the collected data there was good correlations between voltage and concentration and their relationship were approximately linear. Therefore, it is possible to use noninvasive methods to predict the glucose or bilirubin concentration. In vivo experiments for glucose were carried out with 19 persons in training phase, and five persons were used for testing the model. The glucose behavior model was built into the mobile application. The average glucose concentrations from the transmittance and reflectance mode were obtained. The average percentage error was 8.27 and root mean square error was 18.52 mg/dL. Conclusions: From this research, it can be inferred that the noninvasive optical methods implemented on wireless sensors and smartphones could form a system that can be used at any time and any place in the future as an alternative to traditional invasive blood glucose and bilirubin measurement methods.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3851    
    Printed115    
    Emailed1    
    PDF Downloaded267    
    Comments [Add]    
    Cited by others 8    

Recommend this journal