Background: The tracking devices could help measuring the heart rate and energy expenditure and recognizing the user's activity. The calorie measurement is a significant achievement for the fitness tracking and the continuous health monitoring. Methods: In this paper, a combination of an accelerometer and a photoplethysmography (PPG) sensor is implemented to calculate the calories consumed. These sensors were mounted next to each other and then were placed on the ankle and finger by flat cable. The sensed data are transferred via Bluetooth to a smartphone in a serial and real-time manner. An Android App is designed to display the user's health data. The average amount of consumed energy is obtained from the combination of the accelerometer sensor based on the laws of motion and the PPG sensor based on the heart rate data. Results: The designed system is tested on 10 nonathlete males and 10 nonathlete females randomly. By applying thevelet, the value of the acceleration signal variance was reduced from 3.2 to 0.8. The correlation between PPG and pulse oximeter was 0.9. Moreover, the correlation of the accelerometer and treadmill was 0.9. The root mean square error (RMSE) and the P value of the calorie output from PPG and pulse oximeter are 0.53 and 0.008, respectively. The RMSE and the P value of the calories output from the accelerometer and the treadmill are 0.42 and 0.007, respectively. Conclusion: Our device validity and reliability were good by comparing it with a typical smart band, smart watch, and smartphone available in the market. The combined PPG and the accelerometer sensors were compared with the gold standard, the pulse oximeter, and the treadmill. According to the results, there is no significant difference in the values obtained. Therefore, a mobile system is augmented with the wireless accelerometer and PPG that are connected to a smartphone. The system could be carried out with the user at any time and any place.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed4163    
    Printed148    
    Emailed0    
    PDF Downloaded566    
    Comments [Add]    
    Cited by others 6    

Recommend this journal