Computationally efficient system matrix calculation techniques in computed tomography iterative reconstruction


1 Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences; Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran
2 Department of Radiology and Physics, University of British Columbia; Department of Integrative Oncology, BC Cancer Research Centre, Vancouver, BC, Canada

Correspondence Address:
Dr. Hossein Ghadiri
Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmss.JMSS_29_19

Rights and Permissions

Background: Relative to classical methods in computed tomography, iterative reconstruction techniques enable significantly improved image qualities and/or lowered patient doses. However, the computational speed is a major concern for these iterative techniques. In the present study, we present a method for fast system matrix calculation based on the line integral model (LIM) to speed up the computations without compromising the image quality. In addition, we develop a hybrid line–area integral model (AIM) that highlights the advantages of both LIM and AIMs. Methods: The contributing detectors for a given pixel and a given projection view, and the length of corresponding intersection lines with pixels, are calculated using our proposed algorithm. For the hybrid method, the respective narrow-angle fan beam was modeled by multiple equally spaced lines. The computed system matrix was evaluated in the context of reconstruction using the simultaneous algebraic reconstruction technique (SART) as well as maximum likelihood expectation maximization (MLEM). Results: The proposed LIM offers a considerable reduction in calculation times compared to the standard Siddon algorithm: 2.9 times faster. Differences in root mean square error and peak signal-to-noise ratio were not significant between the proposed LIM and the Siddon algorithm for both SART and MLEM reconstruction methods (P > 0.05). Meanwhile, the proposed hybrid method resulted in significantly improved image qualities relative to LIM and the Siddon algorithm (P < 0.05), though computations were 4.9 times more intensive than the proposed LIM. Conclusion: We have proposed two fast algorithms to calculate the system matrix. The first is based on LIM and was faster than the Siddon algorithm, with matched image quality, whereas the second method is a hybrid LIM–AIM that achieves significantly improved images though with its computational requirements.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed4009    
    Printed166    
    Emailed0    
    PDF Downloaded301    
    Comments [Add]    

Recommend this journal